Skip to main content
Firefighting & Suction Hose PVC/Layflat Suction & Delivery Measured by Internal Diameter (ID)

1" (25 mm) Australian Firefighting Layflat / Reel Hose — 100m Friction Loss Chart & Calculator

ID-measured 25 mm firefighting delivery hose (Australian AS 2792 / rural slip-on reel style). Rated 1000 kPa continuous / 1200 kPa max working pressure; higher wall roughness (0.005 mm, C=140) and sharp kinks increase friction rapidly above 100 L/min. Uses Camlock, Storz, or BSP tail couplings.

Switch Run Length (1" Fire Hose (25 mm))
True Mean ID
25 mm
Outside Dia (OD)
31 mm
Wall Thickness
3 mm
PN Rating (20°C)
1200 kPa 122 m max · 1000 kPa warn
Derated (40°C)
1200 kPa Reinforced hose
Safe Flow ≤1.5 m/s
44 L/min Hammer >71 L/min
Fitting System
Camlock, Storz, BIC or BSP Hose Tail
Zero-JS Engineering Reference Table · 20°C Water

1" Fire Hose (25 mm) Friction Loss & Velocity Chart over 100 Metres

ID: 25 mm · ε = 0.005 mm · Hazen-Williams C = 140

Flow (L/min) Flow (L/hr) Velocity (m/s) Darcy Head (100m) Darcy Drop (kPa) Hazen-W C=140 (m) Drop (PSI) Safety Status
10 600 0.34 0.77 m 7.5 kPa 0.72 m 1.1 psi Safe (≤1.5 m/s)
20 1,200 0.68 2.57 m 25.3 kPa 2.61 m 3.7 psi Safe (≤1.5 m/s)
30 1,800 1.02 5.27 m 51.7 kPa 5.53 m 7.5 psi Safe (≤1.5 m/s)
40 2,400 1.36 8.80 m 86.3 kPa 9.42 m 12.5 psi Safe (≤1.5 m/s)
50 3,000 1.70 13.13 m 128.8 kPa 14.24 m 18.7 psi Caution (1.5–2.4 m/s)
60 3,600 2.04 18.22 m 178.7 kPa 19.96 m 25.9 psi Caution (1.5–2.4 m/s)
70 4,200 2.38 24.07 m 236.0 kPa 26.56 m 34.2 psi Caution (1.5–2.4 m/s)
80 4,800 2.72 30.66 m 300.6 kPa 34.01 m 43.6 psi Water Hammer (>2.4 m/s)
85 5,100 2.89 34.22 m 335.6 kPa 38.05 m 48.7 psi Water Hammer (>2.4 m/s)

Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.

Fire & Suction HosePVC/Layflat Suction & Delivery · ID-Measured

Interactive 1" Fire Hose (25 mm) (100m) Pump & Friction Solver

Pre-loaded with 100 m of 1" (25 mm) Australian Firefighting Layflat / Reel Hose (25 mm ID) at 35 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.

1. Pipe Standard & Size

44 AU Specs
Measured By
ID (Bore)
True Bore ID
25 mm
Outside OD
31 mm
Max @ 20°C
1200 kPa

ID-measured 25 mm firefighting delivery hose (Australian AS 2792 / rural slip-on reel style). Rated 1000 kPa continuous / 1200 kPa max working pressure; higher wall roughness (0.005 mm, C=140) and sharp kinks increase friction rapidly above 100 L/min. Uses Camlock, Storz, or BSP tail couplings.

2. Site Run & Hydraulic Conditions

L/min

Equivalent: 2,100 L/hr · 50,400 L/24h

3 × 30 m coils + 1 × 20 m coil
m
+98 kPa uphill
m
Total Suction: 1.82 m / 5.5 m max
m
m
KPA
100% nominal PN rating (≤ 20°C)
°C

3. Fittings & Valves (2)

ΣK = 4.65 · +5.2 m eq. pipe · 0.33 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

Loss: 0.32 m (3.2 kPa · +5.0 m eq.)

1

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DDifferent fitting systemInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

0
Rural Barbed 90° ElbowK=1.9 · 85DDifferent fitting systemInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

0
Rural Barbed Tee (Branch)K=2.4 · 110DDifferent fitting systemInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12DDifferent fitting system

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

0
Metric Compression 90° ElbowK=0.75 · 32DDifferent fitting system

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

0
Metric Compression Tee (Branch)K=1.2 · 55DDifferent fitting system

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

0

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.2 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (1" Fire Hose (25 mm)) and active pump category (240V Tank Jet Pump).

240V Pressure SystemsAU Supplier

240V Rainwater Tank Jet & Multistage Irrigation Pumps

Automatic constant-pressure pumps sized for Australian rural homes, sheds, and acreage sprinkler zones.

View Matching 240V Tank Jet Pumps
Fire & Suction HoseAU Supplier

Heavy-Duty Suction Hose, Fire Reels & Non-Return Foot Valves

Vacuum-rated 2" helical suction kits and 1"–1.5" layflat hoses with Australian Camlock and Storz fittings.

Price 110m of 1" Fire Hose (25 mm) + Camlock Kits

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Engineering Q&A: 1" Fire Hose (25 mm) over 100 Metres

What is the maximum safe flow rate for 1" Fire Hose (25 mm) (25 mm ID)?

For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, 1" (25 mm) Australian Firefighting Layflat / Reel Hose (25 mm true internal diameter) safely carries up to 44.2 L/min (2,651 L/hr). Above 70.7 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.

How much friction head loss does 100m of 1" Fire Hose (25 mm) have at 35 L/min?

Over a 100 m run at 35 L/min (velocity 1.19 m/s, 20°C water), 1" Fire Hose (25 mm) loses 6.94 m of head (68 kPa / 9.9 PSI) via Darcy-Weisbach, compared with 7.36 m using Hazen-Williams (C=140).

What is the maximum pressure rating of 1" Fire Hose (25 mm) in hot Australian summer conditions?

1" (25 mm) Australian Firefighting Layflat / Reel Hose is rated to 1000 kPa continuous working pressure and 1200 kPa maximum (122.4 m head) using reinforced hose construction (not PE temperature-derated under AS/NZS 4130, though always inspect couplings and avoid kinks).

How much friction does stepping up from 1" Fire Hose (25 mm) to 1 1/2" Fire Hose (38 mm) save over 100m?

At 35 L/min over 100 m, stepping up from 1" Fire Hose (25 mm) (25 mm ID) to 1 1/2" Fire Hose (38 mm) (38 mm ID) cuts pipe friction loss by 86.5%—saving 6.00 m of head (59 kPa) and reducing water velocity from 1.19 m/s down to 0.51 m/s.