Skip to main content
Reverse Gravity-Feed Solver Reverse Bisection Gravity Solver

Stock Trough Gravity-Feed Poly Pipe Flow Calculator (Australia)

Solve backwards for maximum L/min, L/day, and head of cattle supported from a fixed header-tank elevation drop.

Green Stripe · Rural Class BAS 2698.2 · ID-Measured

Stock Trough Gravity Feed

Solve backwards for maximum L/min, L/day, and head of cattle supported from a fixed header-tank elevation drop.

1. Pipe Standard & Size

44 AU Specs
Measured By
ID (Bore)
True Bore ID
31.7 mm
Outside OD
36.1 mm
Max @ 20°C
800 kPa

ID-measured 1 1/4" rural poly (AS 2698.2 Green Stripe). True bore is 31.7 mm compared to 27.0 mm in DN32 Metric PE100 PN12.5. Widely used for paddock trough mains and small farm transfer lines; watch pressure limits on hilly runs or with high-head fire pumps.

2. Site Run & Hydraulic Conditions

= 118 kPa static
m
1 × 200 m coil + 1 × 100 m coil
m
KPA
100% nominal PN rating (≤ 20°C)
°C

3. Fittings & Valves (4)

ΣK = 5.15 · +7.4 m eq. pipe · 0.27 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

0

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

Loss: 0.06 m (0.6 kPa · +1.7 m eq.)

1
Rural Barbed 90° ElbowK=1.9 · 85DInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

Loss: 0.20 m (2.0 kPa · +5.4 m eq.)

2
Rural Barbed Tee (Branch)K=2.4 · 110DInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12D

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

0
Metric Compression 90° ElbowK=0.75 · 32D

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

0
Metric Compression Tee (Branch)K=1.2 · 55D

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

0

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.3 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (1 1/4" Rural Class B) and active pump category (Solar Bore Pump (24V/48V)).

AS 2698.2 Rural PolyAU Supplier

AS 2698.2 Rural Poly Pipe & Matched Rural Fittings

Avoid the metric fitting trap—order ID-measured Green Stripe Class B or Red Line PN9 coils with rural compression or barbed joiners.

Price 300m of 1 1/4" Rural Class B + Barbed Fittings

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Pre-Computed Reverse Darcy-Weisbach Matrix · 200m Run

Gravity-Feed Flow Capacity & Cattle Supported Over 200 Metres

Maximum straight-pipe flow (L/min) and 24-hour cattle capacity at ~60 L/head/day (0 kPa open trough discharge, 20°C). Note how Rural ID-measured pipes consistently outperform same-nominal Metric OD-measured pipes on low-head gravity runs.

Australian Pipe (True ID) 5 m Fall (49 kPa)10 m Fall (98 kPa)20 m Fall (196 kPa)30 m Fall (294 kPa)
3/4" Rural Class B 19.1 mm ID · ID-spec
9.5 L/min
~228 head (14k L/d)
14.1 L/min
~339 head (20k L/d)
21.0 L/min
~503 head (30k L/d)
26.4 L/min
~633 head (38k L/d)
1" Rural Class B 25.3 mm ID · ID-spec
20.4 L/min
~490 head (29k L/d)
30.3 L/min
~727 head (44k L/d)
44.8 L/min
~1,075 head (65k L/d)
56.3 L/min
~1,350 head (81k L/d)
1 1/4" Rural Class B 31.7 mm ID · ID-spec
37.6 L/min
~903 head (54k L/d)
55.7 L/min
~1,336 head (80k L/d)
82.2 L/min
~1,972 head (118k L/d)
103.1 L/min
~2,473 head (148k L/d)
1 1/2" Rural Class B 38.1 mm ID · ID-spec
61.8 L/min
~1,483 head (89k L/d)
91.3 L/min
~2,191 head (131k L/d)
134.5 L/min
~3,229 head (194k L/d)
168.6 L/min
~4,047 head (243k L/d)
2" Rural Class B 50.9 mm ID · ID-spec
134.7 L/min
~3,233 head (194k L/d)
198.5 L/min
~4,764 head (286k L/d)
291.9 L/min
~7,005 head (420k L/d)
365.4 L/min
~8,768 head (526k L/d)
DN25 PE100 PN12.5 21 mm ID · OD-spec
12.3 L/min
~295 head (18k L/d)
18.3 L/min
~439 head (26k L/d)
27.1 L/min
~650 head (39k L/d)
34.1 L/min
~818 head (49k L/d)
DN32 PE100 PN12.5 27 mm ID · OD-spec
24.4 L/min
~584 head (35k L/d)
36.1 L/min
~866 head (52k L/d)
53.4 L/min
~1,281 head (77k L/d)
67.0 L/min
~1,608 head (97k L/d)
DN40 PE100 PN12.5 33.8 mm ID · OD-spec
44.7 L/min
~1,073 head (64k L/d)
66.2 L/min
~1,587 head (95k L/d)
97.6 L/min
~2,342 head (141k L/d)
122.4 L/min
~2,937 head (176k L/d)
DN50 PE100 PN12.5 42.4 mm ID · OD-spec
82.5 L/min
~1,978 head (119k L/d)
121.7 L/min
~2,919 head (175k L/d)
179.1 L/min
~4,299 head (258k L/d)
224.4 L/min
~5,385 head (323k L/d)

Mob-drinking engineering note: Cattle drink in concentrated peaks during hot midday hours. Divide 24-hour capacity by 2–3× (or install oversized trough bowls) to ensure troughs never run dry when a full mob hits the water together.

Pre-Computed Reverse Darcy-Weisbach Matrix · 500m Run

Gravity-Feed Flow Capacity & Cattle Supported Over 500 Metres

Maximum straight-pipe flow (L/min) and 24-hour cattle capacity at ~60 L/head/day (0 kPa open trough discharge, 20°C). Note how Rural ID-measured pipes consistently outperform same-nominal Metric OD-measured pipes on low-head gravity runs.

Australian Pipe (True ID) 5 m Fall (49 kPa)10 m Fall (98 kPa)20 m Fall (196 kPa)30 m Fall (294 kPa)
3/4" Rural Class B 19.1 mm ID · ID-spec
5.6 L/min
~134 head (8k L/d)
8.4 L/min
~200 head (12k L/d)
12.5 L/min
~298 head (18k L/d)
15.7 L/min
~376 head (23k L/d)
1" Rural Class B 25.3 mm ID · ID-spec
12.1 L/min
~290 head (17k L/d)
18.0 L/min
~431 head (26k L/d)
26.7 L/min
~640 head (38k L/d)
33.6 L/min
~806 head (48k L/d)
1 1/4" Rural Class B 31.7 mm ID · ID-spec
22.3 L/min
~536 head (32k L/d)
33.2 L/min
~795 head (48k L/d)
49.1 L/min
~1,178 head (71k L/d)
61.7 L/min
~1,480 head (89k L/d)
1 1/2" Rural Class B 38.1 mm ID · ID-spec
36.8 L/min
~882 head (53k L/d)
54.5 L/min
~1,307 head (78k L/d)
80.5 L/min
~1,933 head (116k L/d)
101.1 L/min
~2,426 head (146k L/d)
2" Rural Class B 50.9 mm ID · ID-spec
80.5 L/min
~1,931 head (116k L/d)
118.9 L/min
~2,853 head (171k L/d)
175.3 L/min
~4,206 head (252k L/d)
219.8 L/min
~5,274 head (316k L/d)
DN25 PE100 PN12.5 21 mm ID · OD-spec
7.3 L/min
~174 head (10k L/d)
10.8 L/min
~260 head (16k L/d)
16.1 L/min
~386 head (23k L/d)
20.3 L/min
~487 head (29k L/d)
DN32 PE100 PN12.5 27 mm ID · OD-spec
14.4 L/min
~346 head (21k L/d)
21.5 L/min
~515 head (31k L/d)
31.8 L/min
~763 head (46k L/d)
40.0 L/min
~960 head (58k L/d)
DN40 PE100 PN12.5 33.8 mm ID · OD-spec
26.6 L/min
~638 head (38k L/d)
39.4 L/min
~946 head (57k L/d)
58.4 L/min
~1,400 head (84k L/d)
73.3 L/min
~1,759 head (106k L/d)
DN50 PE100 PN12.5 42.4 mm ID · OD-spec
49.1 L/min
~1,179 head (71k L/d)
72.7 L/min
~1,745 head (105k L/d)
107.4 L/min
~2,576 head (155k L/d)
134.7 L/min
~3,233 head (194k L/d)

Mob-drinking engineering note: Cattle drink in concentrated peaks during hot midday hours. Divide 24-hour capacity by 2–3× (or install oversized trough bowls) to ensure troughs never run dry when a full mob hits the water together.

On-Site Australian Installation Checklist

Stock Trough Gravity Feed Field Design Rules

  1. 1

    Check True Internal Bore — Avoid the Metric OD Trap

    Gravity systems run on tiny available head (often just 5–15 m). Using DN25 Metric PE100 (21.0 mm ID) instead of 1" Rural (25.3 mm ID) slashes gravity trough flow by roughly 35%!

  2. 2

    Eliminate Air Locks Across Undulating Paddocks

    Low-head gravity lines cannot push trapped air over intermediate humps. Bury pipe on an even grade or fit high-point air-release vents and low-point scour valves.

  3. 3

    Match Full-Flow Low-Pressure Float Valves

    High-pressure town-water float valves have tiny orifices that choke low-head gravity lines. Fit dedicated rural full-flow trough valves (25–50 mm) matched to your supply line.

  4. 4

    Buffer for Mob Drinking Behaviour (~60 L/head/day)

    Cattle drink in mobs around midday—up to 50% of daily intake inside a few hours. Pair generous trough storage volume with a pipe sized for fast recovery rather than bare 24-hour averages.

Frequently Asked Questions: Stock Trough Gravity Feed

How much water will gravity-feed through 1 1/4" Rural poly over 500m with 10m fall?

With 10 m of steady downhill elevation drop over 500 m, 1 1/4" Rural Class B (31.7 mm true ID) gravity-feeds up to 33.2 L/min (47,742 L/day), which equates to ~795 head of cattle at 60 L/head/day before fitting restrictions.

Why does 1" Rural poly outperform DN25 Metric PE100 so heavily on gravity feed?

Over 200 m with 10 m fall, 1" Rural Class B (25.3 mm ID) delivers 30.3 L/min whereas DN25 Metric PE100 PN12.5 (21.0 mm ID) delivers only 18.3 L/min—because gravity flow scales with pipe diameter to roughly the 2.6 power.

How many litres per day should I allow per head of cattle in Australia?

Australian beef cattle typically consume 45–60 L/head/day on average and up to 70–80+ L/head/day for lactating cows during 40°C summer heatwaves. Always design trough storage and gravity pipe recovery for peak summer mob drinking rates.