3/4" Rural Poly Pipe Class B (Green Stripe) — 200m Friction Loss Chart & Calculator
ID-measured rural LDPE/MDPE poly (AS 2698.2 Green Stripe). True bore is 19.1 mm—2.5 mm wider than DN20 Metric PE100 PN12.5 (16.6 mm ID). Requires rural barbed or rural-sized compression fittings; standard metric DN20 fittings will NOT seal on the 22.5 mm OD. Rated 630 kPa recommended working / 800 kPa max at 20°C.
- True Mean ID
- 19.1 mm
- Outside Dia (OD)
- 22.5 mm
- Wall Thickness
- 1.7 mm
- PN Rating (20°C)
- 800 kPa 82 m max · 630 kPa warn
- Derated (40°C)
- 592 kPa 74% AS/NZS 4130 (60 m)
- Safe Flow ≤1.5 m/s
- 26 L/min Hammer >41 L/min
- Fitting System
- Rural Barbed Insert or Rural Compression
3/4" Rural Class B Friction Loss & Velocity Chart over 200 Metres
ID: 19.1 mm · ε = 0.0015 mm · Hazen-Williams C = 150
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (200m) | Darcy Drop (kPa) | Hazen-W C=150 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.58 | 5.46 m | 53.5 kPa | 4.72 m | 7.8 psi | Safe (≤1.5 m/s) |
| 15 | 900 | 0.87 | 11.08 m | 108.7 kPa | 10.00 m | 15.8 psi | Safe (≤1.5 m/s) |
| 20 | 1,200 | 1.16 | 18.38 m | 180.2 kPa | 17.04 m | 26.1 psi | Safe (≤1.5 m/s) |
| 25 | 1,500 | 1.45 | 27.25 m | 267.3 kPa | 25.76 m | 38.8 psi | Safe (≤1.5 m/s) |
| 30 | 1,800 | 1.75 | 37.65 m | 369.2 kPa | 36.11 m | 53.6 psi | Caution (1.5–2.4 m/s) |
| 35 | 2,100 | 2.04 | 49.52 m | 485.6 kPa | 48.04 m | 70.4 psi | Caution (1.5–2.4 m/s) |
| 40 | 2,400 | 2.33 | 62.82 m | 616.0 kPa | 61.52 m | 89.3 psi | Caution (1.5–2.4 m/s) |
| 45 | 2,700 | 2.62 | 77.52 m | 760.2 kPa | 76.51 m | 110.3 psi | Water Hammer (>2.4 m/s) |
| 50 | 3,000 | 2.91 | 93.59 m | 917.8 kPa >PN | 93.00 m | 133.1 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
Step up to 1" Rural Class B & cut friction by 73.8%
Stepping up from 3/4" Rural Class B (19.1 mm ID) to 1" Rural Class B (25.3 mm ID) cuts pipe friction by 73.8% (saving 13.6 m / 133 kPa) and lowers velocity from 1.16 to 0.66 m/s.
Don’t confuse 3/4" Rural Class B (19.1 mm ID) with DN20 PE100 PN12.5 (16.6 mm ID)
DN20 PE100 PN12.5 (16.6 mm ID) has a 2.5 mm smaller bore than 3/4" Rural Class B (19.1 mm ID), causing 1.95× the pipe friction loss (+17.5 m / +172 kPa) and reducing Solar Bore Pump (24V/48V) flow by 7.3 L/min (25.3%).
3/4" Rural Class B vs Next Size Up (1" Rural Class B) — 200 m Run
Length: 200 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive 3/4" Rural Class B (200m) Pump & Friction Solver
Pre-loaded with 200 m of 3/4" Rural Poly Pipe Class B (Green Stripe) (19.1 mm ID) at 20 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsID-measured rural LDPE/MDPE poly (AS 2698.2 Green Stripe). True bore is 19.1 mm—2.5 mm wider than DN20 Metric PE100 PN12.5 (16.6 mm ID). Requires rural barbed or rural-sized compression fittings; standard metric DN20 fittings will NOT seal on the 22.5 mm OD. Rated 630 kPa recommended working / 800 kPa max at 20°C.
2. Site Run & Hydraulic Conditions
Equivalent: 1,200 L/hr · 28,800 L/24h
3. Fittings & Valves (5)
ΣK = 9.65 · +8.3 m eq. pipe · 0.67 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.31 m (3.0 kPa · +3.8 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
Loss: 0.08 m (0.8 kPa · +1.1 m eq.)
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Loss: 0.26 m (2.6 kPa · +3.2 m eq.)
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.2 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.16 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (400 kPa) is safely within 3/4" Rural Class B working rating (630 kPa warning / 800 kPa max).
Total suction head is 1.81 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
3/4" Rural Class B vs. DN20 PE100 PN12.5
DN20 PE100 PN12.5 (16.6 mm ID) has a 2.5 mm smaller bore than 3/4" Rural Class B (19.1 mm ID), causing 1.95× the pipe friction loss (+17.5 m / +172 kPa) and reducing Solar Bore Pump (24V/48V) flow by 7.2 L/min (25.2%).
Step Up to 1" Rural Class B
Stepping up from 3/4" Rural Class B (19.1 mm ID) to 1" Rural Class B (25.3 mm ID) cuts pipe friction by 73.8% (saving 13.6 m / 133 kPa) and lowers velocity from 1.16 to 0.66 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 200 m 3/4" Rural Class B system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
Solar Bore Pump (24V/48V)Active Strong match: delivers 28.4 L/min at 57.3 m head (1.65 m/s) safely within pipe pressure limits. | Solar DC | 28.4 L/min @ 57.3 m 562 kPa · 1.65 m/s | 75 m (735 kPa) | Recommended Match | $1,400–$3,200 AUD | |
240V Multistage Irrigation Pump Strong match: delivers 28.9 L/min at 58.4 m head (1.68 m/s) safely within pipe pressure limits. | 240V AC | 28.9 L/min @ 58.4 m 573 kPa · 1.68 m/s | 62 m (608 kPa) | Recommended Match | $650–$1,450 AUD | |
Single-Impeller Fire Pump Meets target flow at 33.0 L/min (68.0 m head), but note: very low flow on pump curve. | Petrol | 33.0 L/min @ 68.0 m 667 kPa · 1.92 m/s | 70 m (686 kPa) | Capable (Check Sizing) | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Delivers 42.4 L/min at 94.3 m head, but shut-off pressure (961 kPa) exceeds 3/4" Rural Class B max rating (800 kPa). | Petrol | 42.4 L/min @ 94.3 m 925 kPa · 2.46 m/s | 98 m (961 kPa) Exceeds pipe max! | Overpressure Risk | $850–$1,650 AUD | |
240V Tank Jet Pump Delivers 19.6 L/min (98% of 20 L/min target) at 40.1 m head. | 240V AC | 19.6 L/min @ 40.1 m 393 kPa · 1.14 m/s | 46 m (451 kPa) | Undersized Flow | $380–$780 AUD | |
2" Trash / Transfer Pump Delivers 10.5 L/min (53% of 20 L/min target) at 27.9 m head. | Petrol | 10.5 L/min @ 27.9 m 273 kPa · 0.61 m/s | 28 m (275 kPa) | Undersized Flow | $450–$980 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
Use AS 2698.2 Rural 3/4" ID-sized barbed insert fittings (with stainless cobra/worm-drive clamps) or Rural external compression fittings. Standard Metric OD fittings will NOT seal on this pipe's 22.5 mm OD.
- 1 × 24V / 48V Brushless Solar Submersible Bore Pump$1,400–$3,200 AUDInlet 100 mm / Outlet 32 mm · Shut-off 75 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.31 m
- 2 × Rural Poly Barbed 90° Insert ElbowK=3.80 · 0.26 m
- 1 × Rural Poly Barbed Insert JoinerK=1.20 · 0.08 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (3/4" Rural Class B) and active pump category (Solar Bore Pump (24V/48V)).
Off-Grid Solar Bore Kits Sized to Your Total Dynamic Head
Compare 24V/48V brushless submersible kits matched to your calculated head, flow rate, and poly drop-pipe.
AS 2698.2 Rural Poly Pipe & Matched Rural Fittings
Avoid the metric fitting trap—order ID-measured Green Stripe Class B or Red Line PN9 coils with rural compression or barbed joiners.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: 3/4" Rural Class B over 200 Metres
What is the maximum safe flow rate for 3/4" Rural Class B (19.1 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, 3/4" Rural Poly Pipe Class B (Green Stripe) (19.1 mm true internal diameter) safely carries up to 25.8 L/min (1,547 L/hr). Above 41.3 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 200m of 3/4" Rural Class B have at 20 L/min?
Over a 200 m run at 20 L/min (velocity 1.16 m/s, 20°C water), 3/4" Rural Class B loses 18.38 m of head (180 kPa / 26.1 PSI) via Darcy-Weisbach, compared with 17.04 m using Hazen-Williams (C=150).
What is the maximum pressure rating of 3/4" Rural Class B in hot Australian summer conditions?
3/4" Rural Poly Pipe Class B (Green Stripe) is rated to 800 kPa maximum (81.6 m head; 630 kPa continuous working caution) at 20°C under AS 2698.2. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 592 kPa (60.4 m head).
How does 3/4" Rural Class B compare to DN20 PE100 PN12.5 in Australia?
3/4" Rural Class B is measured by Internal Diameter (19.1 mm ID) while DN20 PE100 PN12.5 is measured by Outside Diameter (20 mm OD, leaving 16.6 mm true ID). At 20 L/min over 200 m, the narrower Metric bore experiences 1.95× the friction loss (+17.5 m / +172 kPa), and Rural vs Metric fittings are physically incompatible.