Skip to main content
Green Stripe · Rural Class B AS 2698.2 Measured by Internal Diameter (ID)

2" Rural Poly Pipe Class B (Green Stripe) — 200m Friction Loss Chart & Calculator

Largest standard AS 2698.2 Green Stripe rural poly. True bore is 50.9 mm—substantially larger than DN50 Metric PE100 PN12.5 (42.4 mm ID); DN63 PE100 (53.4 mm ID) is the true metric hydraulic match. Keep total dynamic and shut-off pressures under 630 kPa continuous / 800 kPa peak at 20°C.

Switch Run Length (2" Rural Class B)
Other 2" Pressure Classes (200m)
True Mean ID
50.9 mm
Outside Dia (OD)
57.5 mm
Wall Thickness
3.3 mm
PN Rating (20°C)
800 kPa 82 m max · 630 kPa warn
Derated (40°C)
592 kPa 74% AS/NZS 4130 (60 m)
Safe Flow ≤1.5 m/s
183 L/min Hammer >293 L/min
Fitting System
Rural Barbed Insert or Rural Compression
Zero-JS Engineering Reference Table · 20°C Water

2" Rural Class B Friction Loss & Velocity Chart over 200 Metres

ID: 50.9 mm · ε = 0.0015 mm · Hazen-Williams C = 150

Flow (L/min) Flow (L/hr) Velocity (m/s) Darcy Head (200m) Darcy Drop (kPa) Hazen-W C=150 (m) Drop (PSI) Safety Status
10 600 0.08 0.05 m 0.5 kPa 0.04 m 0.1 psi Safe (≤1.5 m/s)
30 1,800 0.25 0.35 m 3.5 kPa 0.31 m 0.5 psi Safe (≤1.5 m/s)
60 3,600 0.49 1.19 m 11.7 kPa 1.10 m 1.7 psi Safe (≤1.5 m/s)
90 5,400 0.74 2.44 m 23.9 kPa 2.33 m 3.5 psi Safe (≤1.5 m/s)
120 7,200 0.98 4.07 m 39.9 kPa 3.98 m 5.8 psi Safe (≤1.5 m/s)
150 9,000 1.23 6.06 m 59.4 kPa 6.01 m 8.6 psi Safe (≤1.5 m/s)
180 10,800 1.47 8.39 m 82.3 kPa 8.42 m 11.9 psi Safe (≤1.5 m/s)
210 12,600 1.72 11.06 m 108.5 kPa 11.21 m 15.7 psi Caution (1.5–2.4 m/s)
240 14,400 1.97 14.06 m 137.9 kPa 14.35 m 20.0 psi Caution (1.5–2.4 m/s)
270 16,200 2.21 17.38 m 170.4 kPa 17.85 m 24.7 psi Caution (1.5–2.4 m/s)
300 18,000 2.46 21.01 m 206.1 kPa 21.70 m 29.9 psi Water Hammer (>2.4 m/s)
330 19,800 2.70 24.96 m 244.7 kPa 25.88 m 35.5 psi Water Hammer (>2.4 m/s)
360 21,600 2.95 29.21 m 286.4 kPa 30.41 m 41.5 psi Water Hammer (>2.4 m/s)

Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.

Green Stripe · Rural Class BAS 2698.2 · ID-Measured

Interactive 2" Rural Class B (200m) Pump & Friction Solver

Pre-loaded with 200 m of 2" Rural Poly Pipe Class B (Green Stripe) (50.9 mm ID) at 140 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.

1. Pipe Standard & Size

44 AU Specs
Measured By
ID (Bore)
True Bore ID
50.9 mm
Outside OD
57.5 mm
Max @ 20°C
800 kPa

Largest standard AS 2698.2 Green Stripe rural poly. True bore is 50.9 mm—substantially larger than DN50 Metric PE100 PN12.5 (42.4 mm ID); DN63 PE100 (53.4 mm ID) is the true metric hydraulic match. Keep total dynamic and shut-off pressures under 630 kPa continuous / 800 kPa peak at 20°C.

2. Site Run & Hydraulic Conditions

L/min

Equivalent: 8,400 L/hr · 201,600 L/24h

1 × 200 m coil
m
+98 kPa uphill
m
Total Suction: 1.80 m / 5.5 m max
m
m
KPA
100% nominal PN rating (≤ 20°C)
°C

3. Fittings & Valves (5)

ΣK = 9.65 · +22.0 m eq. pipe · 0.65 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

Loss: 0.30 m (3.0 kPa · +10.2 m eq.)

1

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

Loss: 0.08 m (0.8 kPa · +2.8 m eq.)

1
Rural Barbed 90° ElbowK=1.9 · 85DInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

Loss: 0.25 m (2.5 kPa · +8.7 m eq.)

2
Rural Barbed Tee (Branch)K=2.4 · 110DInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12D

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

0
Metric Compression 90° ElbowK=0.75 · 32D

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

0
Metric Compression Tee (Branch)K=1.2 · 55D

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

0

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.4 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (2" Rural Class B) and active pump category (Single-Impeller Fire Pump).

AU Fire & TransferAU Supplier

Australian Petrol Firefighting & Bulk Transfer Pumps

GX-style single-impeller, twin-impeller high-head, and 2" trash transfer pumps ready for rural delivery.

View Matching Single-Impeller Fire Pumps
AS 2698.2 Rural PolyAU Supplier

AS 2698.2 Rural Poly Pipe & Matched Rural Fittings

Avoid the metric fitting trap—order ID-measured Green Stripe Class B or Red Line PN9 coils with rural compression or barbed joiners.

Price 200m of 2" Rural Class B + Barbed Fittings

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Engineering Q&A: 2" Rural Class B over 200 Metres

What is the maximum safe flow rate for 2" Rural Class B (50.9 mm ID)?

For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, 2" Rural Poly Pipe Class B (Green Stripe) (50.9 mm true internal diameter) safely carries up to 183.1 L/min (10,988 L/hr). Above 293.0 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.

How much friction head loss does 200m of 2" Rural Class B have at 140 L/min?

Over a 200 m run at 140 L/min (velocity 1.15 m/s, 20°C water), 2" Rural Class B loses 5.35 m of head (52 kPa / 7.6 PSI) via Darcy-Weisbach, compared with 5.29 m using Hazen-Williams (C=150).

What is the maximum pressure rating of 2" Rural Class B in hot Australian summer conditions?

2" Rural Poly Pipe Class B (Green Stripe) is rated to 800 kPa maximum (81.6 m head; 630 kPa continuous working caution) at 20°C under AS 2698.2. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 592 kPa (60.4 m head).

How does 2" Rural Class B compare to DN50 PE100 PN12.5 in Australia?

2" Rural Class B is measured by Internal Diameter (50.9 mm ID) while DN50 PE100 PN12.5 is measured by Outside Diameter (50 mm OD, leaving 42.4 mm true ID). At 140 L/min over 200 m, the narrower Metric bore experiences 2.40× the friction loss (+7.5 m / +74 kPa), and Rural vs Metric fittings are physically incompatible.