DN90 Metric PE100 PN8 (SDR21, Blue Stripe) — 100m Friction Loss Chart & Calculator
OD-measured 90 mm Metric PE100 (AS/NZS 4130, SDR21, 800 kPa at 20°C). Large 81.2 mm internal bore keeps head loss minimal for 500–650+ L/min transfer pumps and long low-head irrigation supply mains.
- True Mean ID
- 81.2 mm
- Outside Dia (OD)
- 90 mm
- Wall Thickness
- 4.3 mm SDR21
- PN Rating (20°C)
- 800 kPa 82 m max · 680 kPa warn
- Derated (40°C)
- 592 kPa 74% AS/NZS 4130 (60 m)
- Safe Flow ≤1.5 m/s
- 466 L/min Hammer >746 L/min
- Fitting System
- External Full-Bore Metric Compression / Electrofusion
DN90 PE100 PN8 Friction Loss & Velocity Chart over 100 Metres
ID: 81.2 mm · ε = 0.0015 mm · Hazen-Williams C = 150
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (100m) | Darcy Drop (kPa) | Hazen-W C=150 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.03 | 0.00 m | 0.0 kPa | 0.00 m | 0.0 psi | Safe (≤1.5 m/s) |
| 60 | 3,600 | 0.19 | 0.06 m | 0.6 kPa | 0.06 m | 0.1 psi | Safe (≤1.5 m/s) |
| 120 | 7,200 | 0.39 | 0.22 m | 2.1 kPa | 0.20 m | 0.3 psi | Safe (≤1.5 m/s) |
| 180 | 10,800 | 0.58 | 0.45 m | 4.4 kPa | 0.43 m | 0.6 psi | Safe (≤1.5 m/s) |
| 240 | 14,400 | 0.77 | 0.75 m | 7.3 kPa | 0.74 m | 1.1 psi | Safe (≤1.5 m/s) |
| 300 | 18,000 | 0.97 | 1.11 m | 10.9 kPa | 1.12 m | 1.6 psi | Safe (≤1.5 m/s) |
| 360 | 21,600 | 1.16 | 1.55 m | 15.2 kPa | 1.56 m | 2.2 psi | Safe (≤1.5 m/s) |
| 420 | 25,200 | 1.35 | 2.04 m | 20.0 kPa | 2.08 m | 2.9 psi | Safe (≤1.5 m/s) |
| 480 | 28,800 | 1.54 | 2.59 m | 25.4 kPa | 2.66 m | 3.7 psi | Caution (1.5–2.4 m/s) |
| 540 | 32,400 | 1.74 | 3.20 m | 31.4 kPa | 3.31 m | 4.6 psi | Caution (1.5–2.4 m/s) |
| 600 | 36,000 | 1.93 | 3.88 m | 38.0 kPa | 4.03 m | 5.5 psi | Caution (1.5–2.4 m/s) |
| 660 | 39,600 | 2.12 | 4.60 m | 45.2 kPa | 4.80 m | 6.5 psi | Caution (1.5–2.4 m/s) |
| 720 | 43,200 | 2.32 | 5.39 m | 52.8 kPa | 5.64 m | 7.7 psi | Caution (1.5–2.4 m/s) |
| 780 | 46,800 | 2.51 | 6.23 m | 61.1 kPa | 6.55 m | 8.9 psi | Water Hammer (>2.4 m/s) |
| 840 | 50,400 | 2.70 | 7.13 m | 69.9 kPa | 7.51 m | 10.1 psi | Water Hammer (>2.4 m/s) |
| 900 | 54,000 | 2.90 | 8.08 m | 79.2 kPa | 8.53 m | 11.5 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
DN90 PE100 PN8 is the largest standard diameter in this pipe family
With a 81.2 mm true internal bore, DN90 PE100 PN8 safely moves up to 466 L/min at ≤1.5 m/s velocity. If your system demands even greater capacity or higher pressure rating than 800 kPa, consider stepping into Metric PE100 DN63–DN90 PN12.5/PN16 mains.
Why DN90 PE100 wall thickness reduces true internal bore
Under AS/NZS 4130, DN90 Metric PE100 locks the outside diameter at 90 mm so external metric compression fittings seal universally across PN8–PN16. Higher PN classes grow inward (4.3 mm wall → 81.2 mm true ID), slightly increasing friction loss in exchange for 800 kPa pressure safety.
DN90 PE100 PN8 System Head Curve — 100 m Run
Length: 100 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive DN90 PE100 PN8 (100m) Pump & Friction Solver
Pre-loaded with 100 m of DN90 Metric PE100 PN8 (SDR21, Blue Stripe) (81.2 mm ID) at 360 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsOD-measured 90 mm Metric PE100 (AS/NZS 4130, SDR21, 800 kPa at 20°C). Large 81.2 mm internal bore keeps head loss minimal for 500–650+ L/min transfer pumps and long low-head irrigation supply mains.
2. Site Run & Hydraulic Conditions
Equivalent: 21,600 L/hr · 518,400 L/24h
3. Fittings & Valves (6)
ΣK = 9.60 · +34.4 m eq. pipe · 0.66 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.31 m (3.0 kPa · +16.2 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
Loss: 0.02 m (0.2 kPa · +1.0 m eq.)
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Loss: 0.10 m (1.0 kPa · +5.2 m eq.)
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Loss: 0.22 m (2.1 kPa · +11.4 m eq.)
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.6 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.16 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (234 kPa) is safely within DN90 PE100 PN8 working rating (680 kPa warning / 800 kPa max).
Total suction head is 1.81 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
No Direct Rural-vs-Metric Naming Trap
DN90 PE100 PN8 (81.2 mm true ID) does not share an ambiguous Rural/Metric nominal pair. Standard rural Class B poly tops out at 2" (50.9 mm ID), whereas DN63–DN90 Metric PE100 pipes offer larger high-pressure bores.
Largest Standard Bore in This Pipe Family
DN90 PE100 PN8 (81.2 mm ID) is the largest standard coil size in its pipe family. For higher flows or lower friction, consider switching to larger Metric PE100 (DN63–DN90).
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 100 m DN90 PE100 PN8 system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
Single-Impeller Fire PumpActive Strong match: delivers 372.7 L/min at 24.0 m head (1.20 m/s) safely within pipe pressure limits. | Petrol | 372.7 L/min @ 24.0 m 236 kPa · 1.20 m/s | 70 m (686 kPa) | Recommended Match | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Delivers 331.0 L/min at 23.6 m head, but shut-off pressure (961 kPa) exceeds DN90 PE100 PN8 max rating (800 kPa). | Petrol | 331.0 L/min @ 23.6 m 231 kPa · 1.07 m/s | 98 m (961 kPa) Exceeds pipe max! | Overpressure Risk | $850–$1,650 AUD | |
2" Trash / Transfer Pump Delivers 277.7 L/min (77% of 360 L/min target) at 23.1 m head. | Petrol | 277.7 L/min @ 23.1 m 226 kPa · 0.89 m/s | 28 m (275 kPa) | Undersized Flow | $450–$980 AUD | |
240V Multistage Irrigation Pump Delivers 146.6 L/min (41% of 360 L/min target) at 22.1 m head. | 240V AC | 146.6 L/min @ 22.1 m 217 kPa · 0.47 m/s | 62 m (608 kPa) | Undersized Flow | $650–$1,450 AUD | |
240V Tank Jet Pump Delivers 60.4 L/min (17% of 360 L/min target) at 21.8 m head. | 240V AC | 60.4 L/min @ 21.8 m 214 kPa · 0.19 m/s | 46 m (451 kPa) | Undersized Flow | $380–$780 AUD | |
Solar Bore Pump (24V/48V) Delivers 55.2 L/min (15% of 360 L/min target) at 21.8 m head. | Solar DC | 55.2 L/min @ 21.8 m 213 kPa · 0.18 m/s | 75 m (735 kPa) | Undersized Flow | $1,400–$3,200 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
Use AS/NZS 4130 Metric DN90 (90 mm OD) external compression or electrofusion fittings. Rural barbed insert fittings will NOT match this pipe's 81.2 mm bore.
- 1 × Single-Impeller Petrol Firefighting Pump (5.5–6.5 HP GX-Style)$550–$1,150 AUDInlet 40 mm / Outlet 40 mm · Shut-off 70 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.31 m
- 2 × Metric PE100 External Compression 90° ElbowK=1.50 · 0.10 m
- 1 × Metric PE100 External Compression JoinerK=0.25 · 0.02 m
- 1 × Spring-Loaded Brass / Stainless Check ValveK=3.20 · 0.22 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (DN90 PE100 PN8) and active pump category (Single-Impeller Fire Pump).
Australian Petrol Firefighting & Bulk Transfer Pumps
GX-style single-impeller, twin-impeller high-head, and 2" trash transfer pumps ready for rural delivery.
AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings
Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: DN90 PE100 PN8 over 100 Metres
What is the maximum safe flow rate for DN90 PE100 PN8 (81.2 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN90 Metric PE100 PN8 (SDR21, Blue Stripe) (81.2 mm true internal diameter) safely carries up to 466.1 L/min (27,964 L/hr). Above 745.7 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 100m of DN90 PE100 PN8 have at 360 L/min?
Over a 100 m run at 360 L/min (velocity 1.16 m/s, 20°C water), DN90 PE100 PN8 loses 1.55 m of head (15 kPa / 2.2 PSI) via Darcy-Weisbach, compared with 1.56 m using Hazen-Williams (C=150).
What is the maximum pressure rating of DN90 PE100 PN8 in hot Australian summer conditions?
DN90 Metric PE100 PN8 (SDR21, Blue Stripe) is rated to 800 kPa maximum (81.6 m head; 680 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 592 kPa (60.4 m head).