DN25 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) — 100m Friction Loss Chart & Calculator
Classic Australian Rural-vs-Metric trap: DN25 PE100 PN12.5 is 25 mm OD with a 21.0 mm bore—NOT 1" (25.3 mm) ID. At the same flow rate, DN25 PN12.5 suffers ~2.4x the friction loss of 1" Rural Class B; step up to DN32 PE100 (27.0 mm ID) to match 1" Rural hydraulics.
- True Mean ID
- 21 mm
- Outside Dia (OD)
- 25 mm
- Wall Thickness
- 1.9 mm SDR13.6
- PN Rating (20°C)
- 1250 kPa 127 m max · 1050 kPa warn
- Derated (40°C)
- 925 kPa 74% AS/NZS 4130 (94 m)
- Safe Flow ≤1.5 m/s
- 31 L/min Hammer >50 L/min
- Fitting System
- External Full-Bore Metric Compression / Electrofusion
DN25 PE100 PN12.5 Friction Loss & Velocity Chart over 100 Metres
ID: 21 mm · ε = 0.0015 mm · Hazen-Williams C = 150
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (100m) | Darcy Drop (kPa) | Hazen-W C=150 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.48 | 1.74 m | 17.1 kPa | 1.49 m | 2.5 psi | Safe (≤1.5 m/s) |
| 20 | 1,200 | 0.96 | 5.85 m | 57.3 kPa | 5.37 m | 8.3 psi | Safe (≤1.5 m/s) |
| 30 | 1,800 | 1.44 | 11.96 m | 117.3 kPa | 11.38 m | 17.0 psi | Safe (≤1.5 m/s) |
| 40 | 2,400 | 1.92 | 19.94 m | 195.5 kPa | 19.38 m | 28.4 psi | Caution (1.5–2.4 m/s) |
| 50 | 3,000 | 2.41 | 29.68 m | 291.1 kPa | 29.30 m | 42.2 psi | Water Hammer (>2.4 m/s) |
| 60 | 3,600 | 2.89 | 41.13 m | 403.3 kPa | 41.07 m | 58.5 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
Step up to DN32 PE100 PN12.5 & cut friction by 69.8%
Stepping up from DN25 PE100 PN12.5 (21 mm ID) to DN32 PE100 PN12.5 (27 mm ID) cuts pipe friction by 69.8% (saving 6.0 m / 59 kPa) and lowers velocity from 1.20 to 0.73 m/s.
Don’t confuse DN25 PE100 PN12.5 (21 mm ID) with 1" Rural Class B (25.3 mm ID)
DN25 PE100 PN12.5 (21 mm ID) has a 4.3 mm smaller bore than 1" Rural Class B (25.3 mm ID), causing 2.43× the pipe friction loss (+5.1 m / +50 kPa) and reducing 240V Tank Jet Pump flow by 10.4 L/min (24.4%).
DN25 PE100 PN12.5 vs Next Size Up (DN32 PE100 PN12.5) — 100 m Run
Length: 100 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive DN25 PE100 PN12.5 (100m) Pump & Friction Solver
Pre-loaded with 100 m of DN25 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) (21 mm ID) at 25 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsClassic Australian Rural-vs-Metric trap: DN25 PE100 PN12.5 is 25 mm OD with a 21.0 mm bore—NOT 1" (25.3 mm) ID. At the same flow rate, DN25 PN12.5 suffers ~2.4x the friction loss of 1" Rural Class B; step up to DN32 PE100 (27.0 mm ID) to match 1" Rural hydraulics.
2. Site Run & Hydraulic Conditions
Equivalent: 1,500 L/hr · 36,000 L/24h
3. Fittings & Valves (6)
ΣK = 9.60 · +8.9 m eq. pipe · 0.71 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.33 m (3.3 kPa · +4.2 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
Loss: 0.02 m (0.2 kPa · +0.3 m eq.)
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Loss: 0.11 m (1.1 kPa · +1.3 m eq.)
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Loss: 0.24 m (2.3 kPa · +2.9 m eq.)
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.2 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.20 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (305 kPa) is safely within DN25 PE100 PN12.5 working rating (1050 kPa warning / 1250 kPa max).
Total suction head is 1.83 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
1" Rural Class B vs. DN25 PE100 PN12.5
DN25 PE100 PN12.5 (21 mm ID) has a 4.3 mm smaller bore than 1" Rural Class B (25.3 mm ID), causing 2.43× the pipe friction loss (+5.1 m / +50 kPa) and reducing 240V Tank Jet Pump flow by 10.3 L/min (24.8%).
Step Up to DN32 PE100 PN12.5
Stepping up from DN25 PE100 PN12.5 (21 mm ID) to DN32 PE100 PN12.5 (27 mm ID) cuts pipe friction by 69.8% (saving 6.0 m / 59 kPa) and lowers velocity from 1.20 to 0.73 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 100 m DN25 PE100 PN12.5 system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
240V Tank Jet PumpActive Strong match: delivers 31.1 L/min at 35.6 m head (1.50 m/s) safely within pipe pressure limits. | 240V AC | 31.1 L/min @ 35.6 m 349 kPa · 1.50 m/s | 46 m (451 kPa) | Recommended Match | $380–$780 AUD | |
Solar Bore Pump (24V/48V) Strong match: delivers 40.2 L/min at 43.6 m head (1.93 m/s) safely within pipe pressure limits. | Solar DC | 40.2 L/min @ 43.6 m 428 kPa · 1.93 m/s | 75 m (735 kPa) | Recommended Match | $1,400–$3,200 AUD | |
240V Multistage Irrigation Pump Meets target flow at 50.6 L/min (54.9 m head), but note: high velocity (2.43 m/s). | 240V AC | 50.6 L/min @ 54.9 m 538 kPa · 2.43 m/s | 62 m (608 kPa) | Capable (Check Sizing) | $650–$1,450 AUD | |
Single-Impeller Fire Pump Meets target flow at 59.6 L/min (66.4 m head), but note: high velocity (2.87 m/s). | Petrol | 59.6 L/min @ 66.4 m 651 kPa · 2.87 m/s | 70 m (686 kPa) | Capable (Check Sizing) | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Meets target flow at 76.1 L/min (91.3 m head), but note: high velocity (3.66 m/s). | Petrol | 76.1 L/min @ 91.3 m 896 kPa · 3.66 m/s | 98 m (961 kPa) | Capable (Check Sizing) | $850–$1,650 AUD | |
2" Trash / Transfer Pump Delivers 19.6 L/min (78% of 25 L/min target) at 27.8 m head. | Petrol | 19.6 L/min @ 27.8 m 272 kPa · 0.94 m/s | 28 m (275 kPa) | Undersized Flow | $450–$980 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
Use AS/NZS 4130 Metric DN25 (25 mm OD) external compression or electrofusion fittings. Rural barbed insert fittings will NOT match this pipe's 21 mm bore.
- 1 × 240V Constant-Pressure Household & Rainwater Tank Jet Pump$380–$780 AUDInlet 25 mm / Outlet 25 mm · Shut-off 46 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.33 m
- 2 × Metric PE100 External Compression 90° ElbowK=1.50 · 0.11 m
- 1 × Metric PE100 External Compression JoinerK=0.25 · 0.02 m
- 1 × Spring-Loaded Brass / Stainless Check ValveK=3.20 · 0.24 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (DN25 PE100 PN12.5) and active pump category (240V Tank Jet Pump).
240V Rainwater Tank Jet & Multistage Irrigation Pumps
Automatic constant-pressure pumps sized for Australian rural homes, sheds, and acreage sprinkler zones.
AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings
Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: DN25 PE100 PN12.5 over 100 Metres
What is the maximum safe flow rate for DN25 PE100 PN12.5 (21 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN25 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) (21 mm true internal diameter) safely carries up to 31.2 L/min (1,870 L/hr). Above 49.9 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 100m of DN25 PE100 PN12.5 have at 25 L/min?
Over a 100 m run at 25 L/min (velocity 1.20 m/s, 20°C water), DN25 PE100 PN12.5 loses 8.66 m of head (85 kPa / 12.3 PSI) via Darcy-Weisbach, compared with 8.12 m using Hazen-Williams (C=150).
What is the maximum pressure rating of DN25 PE100 PN12.5 in hot Australian summer conditions?
DN25 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) is rated to 1250 kPa maximum (127.5 m head; 1050 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 925 kPa (94.3 m head).
How does DN25 PE100 PN12.5 compare to 1" Rural Class B in Australia?
1" Rural Class B is measured by Internal Diameter (25.3 mm ID) while DN25 PE100 PN12.5 is measured by Outside Diameter (25 mm OD, leaving 21 mm true ID). At 25 L/min over 100 m, the narrower Metric bore experiences 2.43× the friction loss (+5.1 m / +50 kPa), and Rural vs Metric fittings are physically incompatible.