DN20 Metric PE100 PN8 (SDR21, Blue Stripe) — 300m Friction Loss Chart & Calculator
OD-measured 20 mm Metric PE100 (AS/NZS 4130, SDR21 nominal). AS/NZS 4130 minimum wall floor of 1.6 mm applies to DN20 SDR21/17/13.6, yielding 16.6 mm mean ID—significantly narrower than 3/4" Rural Class B (19.1 mm ID). Uses metric 20 mm external compression fittings.
- True Mean ID
- 16.6 mm
- Outside Dia (OD)
- 20 mm
- Wall Thickness
- 1.6 mm SDR21
- PN Rating (20°C)
- 800 kPa 82 m max · 680 kPa warn
- Derated (40°C)
- 592 kPa 74% AS/NZS 4130 (60 m)
- Safe Flow ≤1.5 m/s
- 19 L/min Hammer >31 L/min
- Fitting System
- External Full-Bore Metric Compression / Electrofusion
DN20 PE100 PN8 Friction Loss & Velocity Chart over 300 Metres
ID: 16.6 mm · ε = 0.0015 mm · Hazen-Williams C = 150
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (300m) | Darcy Drop (kPa) | Hazen-W C=150 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.77 | 15.93 m | 156.2 kPa | 14.02 m | 22.7 psi | Safe (≤1.5 m/s) |
| 15 | 900 | 1.16 | 32.42 m | 318.0 kPa | 29.71 m | 46.1 psi | Safe (≤1.5 m/s) |
| 20 | 1,200 | 1.54 | 53.85 m | 528.1 kPa | 50.62 m | 76.6 psi | Caution (1.5–2.4 m/s) |
| 25 | 1,500 | 1.93 | 79.96 m | 784.1 kPa | 76.52 m | 113.7 psi | Caution (1.5–2.4 m/s) |
| 30 | 1,800 | 2.31 | 110.56 m | 1084.3 kPa >PN | 107.26 m | 157.3 psi | Caution (1.5–2.4 m/s) |
| 35 | 2,100 | 2.70 | 145.53 m | 1427.2 kPa >PN | 142.70 m | 207.0 psi | Water Hammer (>2.4 m/s) |
| 38 | 2,280 | 2.93 | 168.56 m | 1653.0 kPa >PN | 166.18 m | 239.8 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
Step up to DN25 PE100 PN8 & cut friction by 71.4%
Stepping up from DN20 PE100 PN8 (16.6 mm ID) to DN25 PE100 PN8 (21.6 mm ID) cuts pipe friction by 71.4% (saving 23.2 m / 227 kPa) and lowers velocity from 1.16 to 0.68 m/s.
Don’t confuse DN20 PE100 PN8 (16.6 mm ID) with 3/4" Rural Class B (19.1 mm ID)
DN20 PE100 PN8 (16.6 mm ID) has a 2.5 mm smaller bore than 3/4" Rural Class B (19.1 mm ID), causing 1.95× the pipe friction loss (+15.8 m / +155 kPa) and reducing 240V Tank Jet Pump flow by 4.7 L/min (28.9%).
DN20 PE100 PN8 vs Next Size Up (DN25 PE100 PN8) — 300 m Run
Length: 300 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive DN20 PE100 PN8 (300m) Pump & Friction Solver
Pre-loaded with 300 m of DN20 Metric PE100 PN8 (SDR21, Blue Stripe) (16.6 mm ID) at 15 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsOD-measured 20 mm Metric PE100 (AS/NZS 4130, SDR21 nominal). AS/NZS 4130 minimum wall floor of 1.6 mm applies to DN20 SDR21/17/13.6, yielding 16.6 mm mean ID—significantly narrower than 3/4" Rural Class B (19.1 mm ID). Uses metric 20 mm external compression fittings.
2. Site Run & Hydraulic Conditions
Equivalent: 900 L/hr · 21,600 L/24h
3. Fittings & Valves (6)
ΣK = 9.60 · +7.0 m eq. pipe · 0.65 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.31 m (3.0 kPa · +3.3 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
Loss: 0.02 m (0.2 kPa · +0.2 m eq.)
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Loss: 0.10 m (1.0 kPa · +1.1 m eq.)
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Loss: 0.22 m (2.1 kPa · +2.3 m eq.)
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.1 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.16 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (537 kPa) is safely within DN20 PE100 PN8 working rating (680 kPa warning / 800 kPa max).
Total suction head is 1.81 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
3/4" Rural Class B vs. DN20 PE100 PN8
DN20 PE100 PN8 (16.6 mm ID) has a 2.5 mm smaller bore than 3/4" Rural Class B (19.1 mm ID), causing 1.95× the pipe friction loss (+15.8 m / +155 kPa) and reducing Solar Bore Pump (24V/48V) flow by 6.4 L/min (26.5%).
Step Up to DN25 PE100 PN8
Stepping up from DN20 PE100 PN8 (16.6 mm ID) to DN25 PE100 PN8 (21.6 mm ID) cuts pipe friction by 71.4% (saving 23.2 m / 227 kPa) and lowers velocity from 1.16 to 0.68 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 300 m DN20 PE100 PN8 system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
Solar Bore Pump (24V/48V)Active Strong match: delivers 17.7 L/min at 65.9 m head (1.36 m/s) safely within pipe pressure limits. | Solar DC | 17.7 L/min @ 65.9 m 646 kPa · 1.36 m/s | 75 m (735 kPa) | Recommended Match | $1,400–$3,200 AUD | |
240V Multistage Irrigation Pump Meets target flow at 16.3 L/min (60.0 m head), but note: very low flow on pump curve. | 240V AC | 16.3 L/min @ 60.0 m 588 kPa · 1.25 m/s | 62 m (608 kPa) | Capable (Check Sizing) | $650–$1,450 AUD | |
Single-Impeller Fire Pump Meets target flow at 18.3 L/min (68.9 m head), but note: very low flow on pump curve. | Petrol | 18.3 L/min @ 68.9 m 676 kPa · 1.41 m/s | 70 m (686 kPa) | Capable (Check Sizing) | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Delivers 23.7 L/min at 95.9 m head, but shut-off pressure (961 kPa) exceeds DN20 PE100 PN8 max rating (800 kPa). | Petrol | 23.7 L/min @ 95.9 m 941 kPa · 1.82 m/s | 98 m (961 kPa) Exceeds pipe max! | Overpressure Risk | $850–$1,650 AUD | |
240V Tank Jet Pump Delivers 11.5 L/min (77% of 15 L/min target) at 42.5 m head. | 240V AC | 11.5 L/min @ 42.5 m 417 kPa · 0.89 m/s | 46 m (451 kPa) | Undersized Flow | $380–$780 AUD | |
2" Trash / Transfer Pump Delivers 5.8 L/min (38% of 15 L/min target) at 27.9 m head. | Petrol | 5.8 L/min @ 27.9 m 274 kPa · 0.44 m/s | 28 m (275 kPa) | Undersized Flow | $450–$980 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
+ 1 straight coil-to-coil joiner recommended to connect rolls.
Use AS/NZS 4130 Metric DN20 (20 mm OD) external compression or electrofusion fittings. Rural barbed insert fittings will NOT match this pipe's 16.6 mm bore.
- 1 × 24V / 48V Brushless Solar Submersible Bore Pump$1,400–$3,200 AUDInlet 100 mm / Outlet 32 mm · Shut-off 75 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.31 m
- 2 × Metric PE100 External Compression 90° ElbowK=1.50 · 0.10 m
- 1 × Metric PE100 External Compression JoinerK=0.25 · 0.02 m
- 1 × Spring-Loaded Brass / Stainless Check ValveK=3.20 · 0.22 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (DN20 PE100 PN8) and active pump category (Solar Bore Pump (24V/48V)).
Off-Grid Solar Bore Kits Sized to Your Total Dynamic Head
Compare 24V/48V brushless submersible kits matched to your calculated head, flow rate, and poly drop-pipe.
AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings
Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: DN20 PE100 PN8 over 300 Metres
What is the maximum safe flow rate for DN20 PE100 PN8 (16.6 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN20 Metric PE100 PN8 (SDR21, Blue Stripe) (16.6 mm true internal diameter) safely carries up to 19.5 L/min (1,169 L/hr). Above 31.2 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 300m of DN20 PE100 PN8 have at 15 L/min?
Over a 300 m run at 15 L/min (velocity 1.16 m/s, 20°C water), DN20 PE100 PN8 loses 32.42 m of head (318 kPa / 46.1 PSI) via Darcy-Weisbach, compared with 29.71 m using Hazen-Williams (C=150).
What is the maximum pressure rating of DN20 PE100 PN8 in hot Australian summer conditions?
DN20 Metric PE100 PN8 (SDR21, Blue Stripe) is rated to 800 kPa maximum (81.6 m head; 680 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 592 kPa (60.4 m head).
How does DN20 PE100 PN8 compare to 3/4" Rural Class B in Australia?
3/4" Rural Class B is measured by Internal Diameter (19.1 mm ID) while DN20 PE100 PN8 is measured by Outside Diameter (20 mm OD, leaving 16.6 mm true ID). At 15 L/min over 300 m, the narrower Metric bore experiences 1.95× the friction loss (+15.8 m / +155 kPa), and Rural vs Metric fittings are physically incompatible.