ID-measured 50 mm rigid-helix PVC suction and delivery hose designed to resist vacuum collapse on dam/tank pump suction lines as well as high-flow 2" trash pump discharge. Keep suction lift + friction loss below 5.5 m and delivery pressure below 600 kPa continuous / 800 kPa max.

Switch Run Length (2" Suction/Delivery Hose)
True Mean ID
50 mm
Outside Dia (OD)
58 mm
Wall Thickness
4 mm
PN Rating (20°C)
800 kPa 82 m max · 600 kPa warn
Derated (40°C)
800 kPa Reinforced hose
Safe Flow ≤1.5 m/s
177 L/min Hammer >283 L/min
Fitting System
Camlock, Storz, BIC or BSP Hose Tail
Zero-JS Engineering Reference Table · 20°C Water

2" Suction/Delivery Hose Friction Loss & Velocity Chart over 50 Metres

ID: 50 mm · ε = 0.005 mm · Hazen-Williams C = 140

Flow (L/min) Flow (L/hr) Velocity (m/s) Darcy Head (50m) Darcy Drop (kPa) Hazen-W C=140 (m) Drop (PSI) Safety Status
10 600 0.08 0.01 m 0.1 kPa 0.01 m 0.0 psi Safe (≤1.5 m/s)
30 1,800 0.25 0.10 m 0.9 kPa 0.09 m 0.1 psi Safe (≤1.5 m/s)
60 3,600 0.51 0.33 m 3.2 kPa 0.34 m 0.5 psi Safe (≤1.5 m/s)
90 5,400 0.76 0.67 m 6.6 kPa 0.72 m 1.0 psi Safe (≤1.5 m/s)
120 7,200 1.02 1.12 m 11.0 kPa 1.23 m 1.6 psi Safe (≤1.5 m/s)
150 9,000 1.27 1.67 m 16.4 kPa 1.86 m 2.4 psi Safe (≤1.5 m/s)
180 10,800 1.53 2.32 m 22.8 kPa 2.61 m 3.3 psi Caution (1.5–2.4 m/s)
210 12,600 1.78 3.07 m 30.1 kPa 3.47 m 4.4 psi Caution (1.5–2.4 m/s)
240 14,400 2.04 3.91 m 38.3 kPa 4.45 m 5.6 psi Caution (1.5–2.4 m/s)
270 16,200 2.29 4.84 m 47.5 kPa 5.53 m 6.9 psi Caution (1.5–2.4 m/s)
300 18,000 2.55 5.86 m 57.5 kPa 6.72 m 8.3 psi Water Hammer (>2.4 m/s)
330 19,800 2.80 6.97 m 68.4 kPa 8.02 m 9.9 psi Water Hammer (>2.4 m/s)

Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.

Fire & Suction HosePVC/Layflat Suction & Delivery · ID-Measured

Interactive 2" Suction/Delivery Hose (50m) Pump & Friction Solver

Pre-loaded with 50 m of 2" (50 mm) Heavy-Duty PVC Helical Suction & Delivery Hose (50 mm ID) at 140 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.

1. Pipe Standard & Size

44 AU Specs
Measured By
ID (Bore)
True Bore ID
50 mm
Outside OD
58 mm
Max @ 20°C
800 kPa

ID-measured 50 mm rigid-helix PVC suction and delivery hose designed to resist vacuum collapse on dam/tank pump suction lines as well as high-flow 2" trash pump discharge. Keep suction lift + friction loss below 5.5 m and delivery pressure below 600 kPa continuous / 800 kPa max.

2. Site Run & Hydraulic Conditions

L/min

Equivalent: 8,400 L/hr · 201,600 L/24h

1 × 30 m coil + 1 × 20 m coil
m
+98 kPa uphill
m
Total Suction: 1.82 m / 5.5 m max
m
m
KPA
100% nominal PN rating (≤ 20°C)
°C

3. Fittings & Valves (2)

ΣK = 4.65 · +10.4 m eq. pipe · 0.33 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

Loss: 0.32 m (3.2 kPa · +10.0 m eq.)

1

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DDifferent fitting systemInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

0
Rural Barbed 90° ElbowK=1.9 · 85DDifferent fitting systemInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

0
Rural Barbed Tee (Branch)K=2.4 · 110DDifferent fitting systemInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12DDifferent fitting system

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

0
Metric Compression 90° ElbowK=0.75 · 32DDifferent fitting system

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

0
Metric Compression Tee (Branch)K=1.2 · 55DDifferent fitting system

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

0

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.4 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (2" Suction/Delivery Hose) and active pump category (240V Multistage Irrigation Pump).

240V Pressure SystemsAU Supplier

240V Rainwater Tank Jet & Multistage Irrigation Pumps

Automatic constant-pressure pumps sized for Australian rural homes, sheds, and acreage sprinkler zones.

View Matching 240V Multistage Irrigation Pumps
Fire & Suction HoseAU Supplier

Heavy-Duty Suction Hose, Fire Reels & Non-Return Foot Valves

Vacuum-rated 2" helical suction kits and 1"–1.5" layflat hoses with Australian Camlock and Storz fittings.

Price 50m of 2" Suction/Delivery Hose + Camlock Kits

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Engineering Q&A: 2" Suction/Delivery Hose over 50 Metres

What is the maximum safe flow rate for 2" Suction/Delivery Hose (50 mm ID)?

For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, 2" (50 mm) Heavy-Duty PVC Helical Suction & Delivery Hose (50 mm true internal diameter) safely carries up to 176.7 L/min (10,603 L/hr). Above 282.7 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.

How much friction head loss does 50m of 2" Suction/Delivery Hose have at 140 L/min?

Over a 50 m run at 140 L/min (velocity 1.19 m/s, 20°C water), 2" Suction/Delivery Hose loses 1.48 m of head (14 kPa / 2.1 PSI) via Darcy-Weisbach, compared with 1.64 m using Hazen-Williams (C=140).

What is the maximum pressure rating of 2" Suction/Delivery Hose in hot Australian summer conditions?

2" (50 mm) Heavy-Duty PVC Helical Suction & Delivery Hose is rated to 600 kPa continuous working pressure and 800 kPa maximum (81.6 m head) using reinforced hose construction (not PE temperature-derated under AS/NZS 4130, though always inspect couplings and avoid kinks).