1 1/4" Rural Poly Pipe Class B (Green Stripe) — 100m Friction Loss Chart & Calculator
ID-measured 1 1/4" rural poly (AS 2698.2 Green Stripe). True bore is 31.7 mm compared to 27.0 mm in DN32 Metric PE100 PN12.5. Widely used for paddock trough mains and small farm transfer lines; watch pressure limits on hilly runs or with high-head fire pumps.
- True Mean ID
- 31.7 mm
- Outside Dia (OD)
- 36.1 mm
- Wall Thickness
- 2.2 mm
- PN Rating (20°C)
- 800 kPa 82 m max · 630 kPa warn
- Derated (40°C)
- 592 kPa 74% AS/NZS 4130 (60 m)
- Safe Flow ≤1.5 m/s
- 71 L/min Hammer >114 L/min
- Fitting System
- Rural Barbed Insert or Rural Compression
1 1/4" Rural Class B Friction Loss & Velocity Chart over 100 Metres
ID: 31.7 mm · ε = 0.0015 mm · Hazen-Williams C = 150
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (100m) | Darcy Drop (kPa) | Hazen-W C=150 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.21 | 0.25 m | 2.4 kPa | 0.20 m | 0.4 psi | Safe (≤1.5 m/s) |
| 20 | 1,200 | 0.42 | 0.82 m | 8.1 kPa | 0.72 m | 1.2 psi | Safe (≤1.5 m/s) |
| 40 | 2,400 | 0.84 | 2.78 m | 27.3 kPa | 2.61 m | 4.0 psi | Safe (≤1.5 m/s) |
| 60 | 3,600 | 1.27 | 5.71 m | 56.0 kPa | 5.53 m | 8.1 psi | Safe (≤1.5 m/s) |
| 80 | 4,800 | 1.69 | 9.53 m | 93.5 kPa | 9.42 m | 13.6 psi | Caution (1.5–2.4 m/s) |
| 100 | 6,000 | 2.11 | 14.21 m | 139.3 kPa | 14.23 m | 20.2 psi | Caution (1.5–2.4 m/s) |
| 120 | 7,200 | 2.53 | 19.70 m | 193.2 kPa | 19.95 m | 28.0 psi | Water Hammer (>2.4 m/s) |
| 140 | 8,400 | 2.96 | 26.00 m | 255.0 kPa | 26.54 m | 37.0 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
Step up to 1 1/2" Rural Class B & cut friction by 58.4%
Stepping up from 1 1/4" Rural Class B (31.7 mm ID) to 1 1/2" Rural Class B (38.1 mm ID) cuts pipe friction by 58.4% (saving 2.4 m / 24 kPa) and lowers velocity from 1.06 to 0.73 m/s.
Don’t confuse 1 1/4" Rural Class B (31.7 mm ID) with DN32 PE100 PN12.5 (27 mm ID)
DN32 PE100 PN12.5 (27 mm ID) has a 4.7 mm smaller bore than 1 1/4" Rural Class B (31.7 mm ID), causing 2.15× the pipe friction loss (+4.8 m / +47 kPa) and reducing 240V Tank Jet Pump flow by 6.3 L/min (12.1%).
1 1/4" Rural Class B vs Next Size Up (1 1/2" Rural Class B) — 100 m Run
Length: 100 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive 1 1/4" Rural Class B (100m) Pump & Friction Solver
Pre-loaded with 100 m of 1 1/4" Rural Poly Pipe Class B (Green Stripe) (31.7 mm ID) at 50 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsID-measured 1 1/4" rural poly (AS 2698.2 Green Stripe). True bore is 31.7 mm compared to 27.0 mm in DN32 Metric PE100 PN12.5. Widely used for paddock trough mains and small farm transfer lines; watch pressure limits on hilly runs or with high-head fire pumps.
2. Site Run & Hydraulic Conditions
Equivalent: 3,000 L/hr · 72,000 L/24h
3. Fittings & Valves (5)
ΣK = 9.65 · +13.7 m eq. pipe · 0.55 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.26 m (2.5 kPa · +6.3 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
Loss: 0.07 m (0.7 kPa · +1.7 m eq.)
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Loss: 0.22 m (2.1 kPa · +5.4 m eq.)
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.3 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.06 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (259 kPa) is safely within 1 1/4" Rural Class B working rating (630 kPa warning / 800 kPa max).
Total suction head is 1.76 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
1 1/4" Rural Class B vs. DN32 PE100 PN12.5
DN32 PE100 PN12.5 (27 mm ID) has a 4.7 mm smaller bore than 1 1/4" Rural Class B (31.7 mm ID), causing 2.15× the pipe friction loss (+4.8 m / +47 kPa) and reducing 240V Tank Jet Pump flow by 6.4 L/min (12.6%).
Step Up to 1 1/2" Rural Class B
Stepping up from 1 1/4" Rural Class B (31.7 mm ID) to 1 1/2" Rural Class B (38.1 mm ID) cuts pipe friction by 58.4% (saving 2.4 m / 24 kPa) and lowers velocity from 1.06 to 0.73 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 100 m 1 1/4" Rural Class B system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
240V Tank Jet PumpActive Strong match: delivers 50.9 L/min at 26.5 m head (1.08 m/s) safely within pipe pressure limits. | 240V AC | 50.9 L/min @ 26.5 m 260 kPa · 1.08 m/s | 46 m (451 kPa) | Recommended Match | $380–$780 AUD | |
Solar Bore Pump (24V/48V) Strong match: delivers 52.2 L/min at 26.8 m head (1.10 m/s) safely within pipe pressure limits. | Solar DC | 52.2 L/min @ 26.8 m 262 kPa · 1.10 m/s | 75 m (735 kPa) | Recommended Match | $1,400–$3,200 AUD | |
240V Multistage Irrigation Pump Strong match: delivers 107.6 L/min at 40.5 m head (2.27 m/s) safely within pipe pressure limits. | 240V AC | 107.6 L/min @ 40.5 m 397 kPa · 2.27 m/s | 62 m (608 kPa) | Recommended Match | $650–$1,450 AUD | |
2" Trash / Transfer Pump Meets target flow at 55.3 L/min (27.3 m head), but note: very low flow on pump curve. | Petrol | 55.3 L/min @ 27.3 m 268 kPa · 1.17 m/s | 28 m (275 kPa) | Capable (Check Sizing) | $450–$980 AUD | |
Single-Impeller Fire Pump Meets target flow at 154.5 L/min (58.0 m head), but note: high velocity (3.26 m/s), oversized for target flow. | Petrol | 154.5 L/min @ 58.0 m 569 kPa · 3.26 m/s | 70 m (686 kPa) | Capable (Check Sizing) | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Delivers 184.1 L/min at 71.7 m head, but shut-off pressure (961 kPa) exceeds 1 1/4" Rural Class B max rating (800 kPa). | Petrol | 184.1 L/min @ 71.7 m 703 kPa · 3.89 m/s | 98 m (961 kPa) Exceeds pipe max! | Overpressure Risk | $850–$1,650 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
Use AS 2698.2 Rural 1 1/4" ID-sized barbed insert fittings (with stainless cobra/worm-drive clamps) or Rural external compression fittings. Standard Metric OD fittings will NOT seal on this pipe's 36.1 mm OD.
- 1 × 240V Constant-Pressure Household & Rainwater Tank Jet Pump$380–$780 AUDInlet 25 mm / Outlet 25 mm · Shut-off 46 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.26 m
- 2 × Rural Poly Barbed 90° Insert ElbowK=3.80 · 0.22 m
- 1 × Rural Poly Barbed Insert JoinerK=1.20 · 0.07 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (1 1/4" Rural Class B) and active pump category (240V Tank Jet Pump).
240V Rainwater Tank Jet & Multistage Irrigation Pumps
Automatic constant-pressure pumps sized for Australian rural homes, sheds, and acreage sprinkler zones.
AS 2698.2 Rural Poly Pipe & Matched Rural Fittings
Avoid the metric fitting trap—order ID-measured Green Stripe Class B or Red Line PN9 coils with rural compression or barbed joiners.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: 1 1/4" Rural Class B over 100 Metres
What is the maximum safe flow rate for 1 1/4" Rural Class B (31.7 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, 1 1/4" Rural Poly Pipe Class B (Green Stripe) (31.7 mm true internal diameter) safely carries up to 71.0 L/min (4,262 L/hr). Above 113.7 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 100m of 1 1/4" Rural Class B have at 50 L/min?
Over a 100 m run at 50 L/min (velocity 1.06 m/s, 20°C water), 1 1/4" Rural Class B loses 4.13 m of head (41 kPa / 5.9 PSI) via Darcy-Weisbach, compared with 3.94 m using Hazen-Williams (C=150).
What is the maximum pressure rating of 1 1/4" Rural Class B in hot Australian summer conditions?
1 1/4" Rural Poly Pipe Class B (Green Stripe) is rated to 800 kPa maximum (81.6 m head; 630 kPa continuous working caution) at 20°C under AS 2698.2. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 592 kPa (60.4 m head).
How does 1 1/4" Rural Class B compare to DN32 PE100 PN12.5 in Australia?
1 1/4" Rural Class B is measured by Internal Diameter (31.7 mm ID) while DN32 PE100 PN12.5 is measured by Outside Diameter (32 mm OD, leaving 27 mm true ID). At 50 L/min over 100 m, the narrower Metric bore experiences 2.15× the friction loss (+4.8 m / +47 kPa), and Rural vs Metric fittings are physically incompatible.